| All of the electrodes listed below should be stored dry at room temp when in unopened cartons | |||
| Electrode Classification | Recommended Storage open Boxes | Holding Oven | Reconditioning |
| E-XX10 | Dry @ room temp | Not Recommended | Not done |
| E-XX11 | Dry @ room temp | Not Recommended | Not done |
| E-XX12 | Dry @ room temp | Not Recommended | Not done |
| E-XX13 | Dry @ room temp | Not Recommended | Not done |
| E-XX14 | 150 - 200 F | 150 - 200 F | 250 - 300 F 1 hr. |
| E-XX20 | 150 - 200 F | 150 - 200 F | 250 - 300 F 1 hr. |
| E-XX24 | 150 - 200 F | 150 - 200 F | 250 - 300 F 1 hr. |
| E-XX27 | 150 - 200 F | 150 - 200 F | 250 - 300 F 1 hr. |
| E-60 or 7015 | 250 - 450 F | 150 - 200 F | 500 - 600 F 1 hr. |
| E-60 or 7016 | 250 - 450 F | 150 - 200 F | 500 - 600 F 1 hr. |
| E-7018 | 250 - 450 F | 150 - 200 F | 500 - 600 F 1 hr. |
| E-7028 | 250 - 450 F | 150 - 200 F | 500 - 600 F 1 hr. |
| E-80 or 9015 | 250 - 450 F | 200 - 250 F | 600 - 700 F 1 hr. |
| E-80 or 9016 | 250 - 450 F | 200 - 250 F | 600 - 700 F 1 hr. |
| E-80 or 9018 | 250 - 450 F | 200 - 250 F | 600 - 700 F 1 hr. |
| E-90 12015 | 250 - 450 F | 200 - 250 F | 650 - 750 F 1 hr. |
| E-90 12016 | 250 - 450 F | 200 - 250 F | 650 - 750 F 1 hr. |
| E-90 12018 | 250 - 450 F | 200 - 250 F | 650 - 750 F 1 hr. |
| E -XXX-15 or 16 | 250 - 450 F | 150 - 200 F | 450 F 1 hr. |
| Stainless | 250 - 450 F | 150 - 200 F | 450 F 1 hr. | When being reconditioned, electrodes should not be baked for more than 4 hours and should be kept at temp for at least 30 minutes. Baking more than 3 times is not recommended. |